Aqua Flo 475 Series
Quick, Simple, Do-it-Yourself Maintenance
Quick connect disposable cartridges and membrane make for easy βDo-It-Yourselfβ maintenance. With built in auto water shut-offs there is no need to turn off the water supply prior to maintenance.
Because traditional systems require the disinfection of the permanent housing canisters and involve more direct human contact, maintenance can be time consuming. If not done properly, this could result in a contaminated system. With disposable cartridges, you can change them in seconds, reducing the risk of contamination.
Manuals
Spec Sheets
Warranty
Key Features
Four stage filtration:
5 micron sediment pre-filter, 10 micron coconut carbon pre & post filters, quick connect 75 GPD NSF Certified TFC membrane
Bayonet-style, 1/4 turn quick connect disposableΒ cartridges with auto water shut-off
Includes faucetΒ and 3.0 gallon NSF Certified storage tank. (Designer faucets available)
3/8β tubingΒ
for high product flow rate from tank to faucet
Quick connect fittingsΒ labelled tubing for easy installation
Two year warrantyΒ (excluding consumable filter cartridges and RO)
Professionally Engineered for Performance
| Model Description | Stages | Sediment Filter | Pre-Filter | Membrane | Post-Filter | Rating GPD |
Dimensions H Γ W Γ D (in) |
|---|---|---|---|---|---|---|---|
| Aqua Flo 475 PRO | 4 | 5 Micron | 10 Micron Coconut Carbon | TFC | 10 Micron Coconut Carbon | 75 | 14.5 Γ 13 Γ 4.5 |
| Aqua Flo 475 PRO BP | 4 | 5 Micron | 10 Micron Coconut Carbon | TFC | 10 Micron Coconut Carbon | 75 | 16.5 Γ 14.5 Γ 6.25 |
| Replacement Filters / Options |
|---|
| SED-10 (Sediment Filter β 5 Micron) |
| COC-10 Coconut Carbon (Pre & Post 10 Micron) |
| CB-10 Carbon Block (Optional Filter β 10 Micron) |
| GAC-10 Granular Carbon (Optional Filter) |
| RO Membrane 75 GPD TFC |
| FEED WATER GUIDELINES | ||
|---|---|---|
| 475 PRO Item # 20010023 |
475 PRO Booster Pump Item # 20010024 |
|
| Maximum TDS | 2,000 ppm/mg/l | 2,500 ppm/mg/l |
| Feed Water Pressure | 40 to 100 psi | 30 to 70 psi |
| Maximum Hardness | 7 GPG | |
| Maximum Iron | 0.2 ppm/mg/l | |
| Maximum Manganese | 0.05 ppm/mg/l | |
| Maximum Hydrogen Sulphide (H2S) | 0.00 ppm/mg/l | |
| Maximum Turbidity | 1.0 NTU | |
| Temperature Range | 40Β° to 100Β°F (4Β° to 38Β°C) | |
| pH Range | 3.0 to 11.0 | |
| Maximum Chlorine | 2.0 ppm/mg/l | |
| NOTE: Feed water supply must be potable. | ||